Heat Dissipation, Power, and Acoustics (Models HS2 and HD3/4)

Table 19. Heat dissipation and power for InfoPrint 4100 Models HS2 and HD3/4
  Engine (per Engine) HS2 and HD4 Control Unit HD3 Control Unit Air Bearing Buffer Flipper
Sleep Mode Idle Ready Mode Printing (20 lb paper)
50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 or 60 Hz
kVA 1.2 1.2 3.0 3.0 12.5 12 1.7 .5 .55
kW 1.0 1.0 2.0 2.0 12 12 1.5 .5 .34
kBTU/Hr 3.4 3.4 6.8 6.8 41 41 5 1.7 1.2
Rated Load (A) 200V 48 48 48 48 48 48 10 10 2.4
Rated Load (A) 400V 30 - 30 - 30 - - - -
Note:
Engine specifications are per engine. Duplex systems will have two engines and two control units.
Table 20. Power cord information for InfoPrint 4100 models HS2 and HD3/4
Item Supplied Plug and Cable Specifications
Worldwide (except U.S.A and Canada) Chicago, U.S.A. U.S.A. and Canada (except Chicago, U.S.A.)
Plug Type Cable Length Plug Type Cable Length Plug Type Cable Length
Engine none supplied 4.2m (14ft) Hubbell HBL460P9V05 1.8m (6ft) Hubbell HBL460P9V05 4.2m (14ft)
Control Unit See Appendix C 2.8m (9.2ft) See Appendix C 1.8m (6ft) See Appendix C 2.8m (9.2ft)
Flipper See Appendix C 4.2m (14ft) See Appendix C 1.8m (6ft) See Appendix C 4.2m (14ft)
Attention: Outside of the U.S.A. and Canada, the engine power cord is shipped without a plug. Duplex systems will include two engine power cords and two control unit power cords.
Table 21. Declared acoustical noise emissions in accordance with ISO 9296 for InfoPrint 4100 Models HS2 and HD3/4
Declared A-Weighted Sound Power Level, LWAd (B) Declared A-Weighted Sound Pressure Level, LpAm (dB)
Operating Idling Operating Idling
8.8 7.8 65 58
Notes:
  1. LWAd is the statistical upper-limit A-weighted sound power level.
  2. LpAm is the mean A-weighted emission sound pressure level measured at one-meter bystander positions.
  3. 1 B = 10 dB.
  4. All measurements made in conformance with ISO 7779 and declared in conformance with ISO 9296.
  5. Operating levels are measured during continuous running with 20-pound forms.