Using the NPRO and NPRO Page Functions to Advance Forms

NPRO (NonProcess RunOut) moves forms forward through the forms path.

The distance NPRO moves forms depends on your printer configuration. There is a fixed NPRO length that you can increase with two different configuration items. You may want to increase the fixed length, for example, if you are using a postprocessing device.

Two configuration parameters let you extend the NPRO length when END OF FORMS 078A is not indicated:

Note:
If you set the "Pre/postprocessor Extended NPRO" item of an enabled pre/postprocessor to a non-zero value, it takes precedence over the Configure Printer "NPRO Length" item, regardless of the particular values specified.